In construction whether vertical or horizontal there is what we always keep in mind that so called “Tolerance” I am going to post it here in order to easily for you to find, if you can’t remember because there are too many of them, and if you want to read again just simply bookmark the post or make this on your favorites.
Firstly, here is the meaning of “Tolerance” – is the permissible limit or limits of variation of physical dimension, a measured value or physical property of a material or manufactured object.
Variation in Concrete
1. Variation from the plumb
1.1
In the lines and surfaces of columns, walls and in arises
Area
Tolerance
In any story or 6 meter max.
6mm
In 12 meter or more
10mm
1.2
For exposed corner column, control joints, grooves and other conspicuous lines
2. Variation from the level or from the grade indicated on the drawings
2.1
From level around perimeter of the building, at stairs and similar critical locations, shall not vary from more than +/- 10mm from level shown on the drawings.
2.2
In floors, ceiling, beam soffit and arises maximum difference between any two points.
Area
Tolerance
In 3 meter
4mm
In any bay or 6 meter max.
6mm
In 12 meter or more
12mm
2.3
For exposed lintels, sills, horizontal grooves and other conspicuous lines
In any bay or 6 meter max.
6mm
In 12 meter or more
10mm
3. Variation in plan dimensions from the established building gridlines to related columns, walls and partition.
Area
Tolerance
In any bay or 6 meter max.
6mm
In 12 meter or more
10mm
4. Variation in the size and location of the sleeves, floor and wall openings 6mm.